Sulfur Compound Instruments - SO2, H2S, TRS, TS

T100 - SO2 Analyzer    Get Quote

The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level sulfur dioxide. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity.
Ranges: 0-50 ppb to 0-20 ppm.  Learn More

T100 - SO2 Analyzer    Get Quote

The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.
Ranges: 0-50 ppb to 0-20 ppm.  Learn More

T100U - SO2 Analyzer    Get Quote

The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive sulfur dioxide measurements while still meeting the requirements for use as a US EPA compliance analyzer.
Ranges: 0-50 ppb to 0-20 ppm.  Learn More

T100U - SO2 Analyzer    Get Quote

The T100U uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.
Ranges: 0-50 ppb to 0-20 ppm.  Learn More

T101 - H2S Analyzer    Get Quote

The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert hydrogen sulfide to sulfur dioxide. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
Ranges: 0-50 ppb to 0-5 ppm.  Learn More

T101 - H2S Analyzer    Get Quote

The T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.
Ranges: 0-50 ppb to 0-5 ppm.  Learn More

T102 - TRS Analyzer    Get Quote

The Model T102 uses a high temperature external converter set at 850°C to allow conversion of hydrogen sulfide, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to sulfur dioxide at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
Ranges: 0-50 ppb to 0-10 ppm.  Learn More

T102 - TRS Analyzer    Get Quote

The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%.
Ranges: 0-50 ppb to 0-10 ppm.  Learn More

T100H - SO2 Analyzer    Get Quote

The Model T100H SO2 analyzer uses the proven UV fluorescence principle with the high measurement ranges and interferent rejection needed for extractive source monitoring. The Model T100H provides a simple but precise solution for a broad range of CEM and stack testing applications. The instrument design provides minimal quenching by O2 or CO2 and less than a 0.1% response to water in the sample. Additionally, special optical filtering reduces the effects of NO interference.
Ranges: 0-10 ppm to 0-5,000 ppm.  Learn More

T100H - SO2 Analyzer    Get Quote

The Model T100H SO2 analyzer uses the proven UV fluorescence principle with the high measurement ranges and interferent rejection needed for extractive source monitoring. The Model T100H provides a simple but precise solution for a broad range of CEM and stack testing applications.
Ranges: 0-10 ppm to 0-5,000 ppm.  Learn More